Removing Hydrogen Sulphide Gas from Water

What is hydrogen sulphide? 
Hydrogen sulphide (H2S) is a dissolved gas that gives water a characteristic "rotten egg" taste and odor. It corrodes piping, creates odors in the house, and turns water black. Homemakers will notice that it can change sterling silver to a black color almost instantly. H2S can cause odor problems at a concentration level as low as 0.05 mg/L. 
H2S in well water 
H2S often occurs naturally in well water, or can be caused by the presence of sulphate reducing bacteria in a well or water system. Since bacteria are the most common cause, treatment to control them should be tried first. Shock chlorination is the standard treatment for control of sulphate reducing and iron bacteria in a well (see Agri-fax 716 (D12) Shock Chlorination and Iron Bacteria Control ). 
H2S in dugout water 
H2S may also be present in dugout water, particularly during the winter and early spring. It is a by-product of decomposing weeds and algae and is caused by a lack of dissolved oxygen in the water. A good dugout maintenance program combined with dugout aeration will prevent this problem from occurring. (See Agri-fax 716 (B31) Dugout Maintenance and Agri-fax 716 (B36) Aerating Dugouts with Compressed Air ). 
H2S in water heaters 
Sometimes H2S may only be present in the household hot water. This condition is caused by a biochemical reaction between sulphates in the water, sulphate reducing bacteria, a magnesium rod in the hot water heater or organic matter in the water. If the odor problem in the water heater is caused by heat loving sulphate reducing bacteria, disinfect the water heater with chlorine bleach or hydrogen peroxide. Sometimes the reaction with the magnesium rod is the cause of odor problem. The purpose of the magnesium rod is to prevent corrosion of the water heater. Removing the magnesium rod will often prevent the odor problem, but will void the warranty and lead to the possible earlier deterioration of the tank. If corrosion is a concern, the magnesium rod can be replaced with a zinc rod. Try disinfecting the tank with chlorine bleach or hydrogen peroxide first before using any of the more drastic measures (See Agri-fax 716 (C33) Odor Control in Hot Water Heaters). 
Water treatment options for removing hydrogen sulphide
  Chlorination and sand filter 
One method for removal of H2S is to install a chlorine feeder and a sand filter. The H2S is oxidized by the chlorine and any insoluble sulphide particles that form are removed by a sand or crushed anthracite filter. Approximately 2 mg/L chlorine must be added to remove 1 mg/L H2S. It may be necessary to install a small cartridge filter containing activated carbon on the drinking water tap to eliminate the chlorine taste. A full sized carbon filter is often used to remove the chlorine from the distribution system. This is an excellent alternative for situations where the water contains some iron along with the H2S. 
Chlorination and activated carbon filter 
The second method is to install a chlorine feeder and an activated carbon filter. As with the previous method, the H2S is oxidized by the chlorine and the insoluble sulphide particles are removed by the activated carbon filter. This filter also removes any residual chlorine that is left after oxidization of the hydrogen sulphide. An activated carbon filter requires a lower backwash rate than a sand filter, but a sand filter has a higher maximum service flow rate. This system is most appropriate in situations where there is only H2S present and no significant amount of iron. The chlorinator shown in Figure 1. is wired to the pressure switch so that the chlorinator is activated when the water pump switches on. The retention tank is installed to ensure sufficient mixing and contact time to complete the oxidation process. It should be large enough to retain water for at least 5 minutes at peak filter capacity (as a minimum, a 42 gallon retention tank is recommended). A valve should be provided at the bottom of the retention tank to drain any sediment. Chlorine test valves should be installed just after the pressure tank and just before the activated carbon filter. These are needed to help check the chlorine level in the treatment system. 